ABG-HEPARIN-DILUTION
medical
runtime_error
ai_generated
true
AI instructs to use heparinized syringe for arterial blood gas from an arterial line, causing inaccurate results
ID: medical/art-line-blood-gas-heparin
90%Fix Rate
87%Confidence
1Evidence
2024-08-22First Seen
Version Compatibility
| Version | Status | Introduced | Deprecated | Notes |
|---|---|---|---|---|
| Radiometer ABL90 FLEX | active | — | — | — |
| Siemens RAPIDPoint 500 | active | — | — | — |
| GEM Premier 5000 | active | — | — | — |
| BD Vacutainer PST | active | — | — | — |
Root Cause
Arterial line dead space contains heparinized flush solution; aspirating 3-5 mL discard before sample is mandatory. Using heparinized syringes for the discard or adding excess heparin can dilute the sample, causing falsely low pCO2, pO2, and electrolytes.
generic中文
动脉导管死腔含有肝素化冲洗液;必须在采样前抽出3-5 mL弃去。对弃去液使用肝素化注射器或添加过多肝素可能稀释样本,导致pCO2、pO2和电解质假性降低。
Official Documentation
https://www.radiometer.com/en-us/blood-gas-testing/arterial-blood-gas-samplingWorkarounds
-
95% success Use a non-heparinized syringe for the discard sample. After discarding 3-5 mL (or 2x dead space), attach a fresh non-heparinized syringe to collect the ABG sample. If using a pre-heparinized syringe, ensure the liquid heparin is fully expelled before filling with blood.
Use a non-heparinized syringe for the discard sample. After discarding 3-5 mL (or 2x dead space), attach a fresh non-heparinized syringe to collect the ABG sample. If using a pre-heparinized syringe, ensure the liquid heparin is fully expelled before filling with blood.
-
90% success Alternatively, use a balanced heparin syringe (e.g., PICO70) with minimal liquid heparin, and fill to the exact mark without excess. Do not use additional liquid heparin.
Alternatively, use a balanced heparin syringe (e.g., PICO70) with minimal liquid heparin, and fill to the exact mark without excess. Do not use additional liquid heparin.
中文步骤
使用非肝素化注射器采集弃去样本。弃去3-5 mL(或2倍死腔体积)后,连接新的非肝素化注射器采集ABG样本。如果使用预肝素化注射器,确保在采集血液前完全排出液体肝素。
或者,使用平衡肝素注射器(如PICO70),其液体肝素含量极少,并精确填充至标记线,不要过量。不要额外添加液体肝素。
Dead Ends
Common approaches that don't work:
-
65% fail
Excessive discard volume can cause iatrogenic anemia in small patients and does not fix the heparin contamination if the syringe itself is heparinized.
-
80% fail
This can cause hemolysis and air bubble introduction, further corrupting pO2 and potassium values.